FUNCTION eis_density, fit1, fit2, ratio, line1=line1, line2=line2, $
                      isothermal=isothermal, no_yshift=no_yshift, quiet=quiet, $
                      yshift_wvl=yshift_wvl, $
                      ioneqfile=ioneqfile, abundfile=abundfile, $
                      calib=calib

;+
; NAME
;
;     EIS_DENSITY
;
; PROJECT
;
;     Hinode/EIS
;
; EXPLANATION
;
;     This routine takes as input two fit structures produced by
;     eis_auto_fit and assumes that they correspond to the denominator
;     and numerator lines of a density diagnostic. With the additional
;     input of a theoretical line ratio curve, the routine computes
;     the density at each pixel in the raster.
;
;     A column depth is also calculated for each pixel using the
;     emission measure method. The alternative isothermal method is
;     also available as an option.
;
;     For more details about densities, column depths and filling
;     factors please consult EIS Software Note #15 which is available
;     within Solarsoft at:
;
;     $SSW/hinode/eis/doc/eis_notes/15_DENSITY/eis_swnote_15.pdf
;
; INPUTS
;
;     FIT1   A structure in the format output by eis_auto_fit,
;            representing the denominator line of the density
;            sensitive line ratio.
;
;     FIT2   A structure in the format output by eis_auto_fit,
;            representing the numerator line of the density
;            sensitive line ratio.
;
;     RATIO  A structure in the format output by
;            eis_chianti_dens_ratio representing the theoretical ratio
;            of the two lines as a function of density.
;
; OPTIONAL INPUTS
;
;     LINE1  If the FIT1 structure contains fits for multiple lines,
;            then LINE1 specifies the index of the line to be used.
;
;     LINE2  If the FIT2 structure contains fits for multiple lines,
;            then LINE2 specifies the index of the line to be used.
;
;     NO_YSHIFT By default the routine automatically shifts the
;               intensity array of the numerator line in the Y
;               direction by the pixel amount given by
;               EIS_CCD_OFFSET. Setting this keyword prevents the
;               shift from being performed.
;
;     YSHIFT_WVL This allows a specific wavelength to be specified
;                through which the intensity arrays are aligned with
;                each other. For example, if you were studying the Fe
;                XIV 264/274 ratio, but wanted to align the output
;                density map with Fe XII
;                195, then you would specify yshift_wvl=195.12.
;
;     IONEQFILE  The name of an ion balance file to use when computing
;                the column depth. The default is to use the standard
;                ion balance file in CHIANTI (!ioneq_file).
;
;     ABUNDFILE  The name of an element abundance file to use when
;                computing the column depth. The default is to use the
;                'sun_coronal_ext.abund' file in CHIANTI. If
;                this doesn't exist then the !abund_file is
;                used (a photospheric abundance file).
;
;     CALIB  This allows the EIS calibration to be modified, changing
;            the output intensity and error arrays. One of the
;            following values should be set:

;            0 - no effect
;            1 - Del Zanna (2013) calibration is implemented.
;            2 - Del Zanna (2013) calibration, and the
;                /correct_sensitivity correction is "undone".
;            3 - Warren et al. (2014) calibration is implemented.
;            4 - Warren et al. (2014) calibration, and the
;                /correct_sensitivity correction is "undone". 
;
;            WARNING: before using this keyword, the user should know
;            what calibration options were applied in the original
;            call to eis_prep. See the EIS wiki for more details
;            (http://solarb.mssl.ucl.ac.uk:8080/eiswiki/Wiki.jsp?page=EISCalibration)
;
; KEYWORDS
;
;     ISOTHERMAL Two approximations are available when computing the
;                column depth. The default is the emission measure
;                approach. Setting /ISOTHERMAL will use the isothermal
;                approach. A document is available on the EIS wiki
;                describing the difference.
;
;     QUIET      If set, then information messaages will not be
;                printed to the screen.
;
; OUTPUTS
;
;     Returns a structure with the following tags:
;
;      .ldens   Logarithm (base 10) of the electron number density
;               (cm^-3).
;      .dens    Electron number density (cm^-3).
;      .lo      The log of the lower limit to the density (cm^-3).
;      .hi      The log of the upper limit to the density (cm^-3).
;      .coldepth The column depth of the plasma (cm).
;      .coldepth_err  Error on column depth (cm).
;      .rat     Value of the observed emission line ratio.
;      .arcsec  Scalar giving factor to convert cm to arcsec (for
;               column depth).
;      .abundfile  Name of abundance file used in calculation.
;      .ioneqfile  Name of ion balance file used in calculation.
;      .missing Value for missing data used in the arrays.
;      .calib   Stores the option used for the CALIB keyword.
;
;     Each of the above quantities has the same dimensions as the
;     intensity arrays of the input fit structures.
;
;     Note that the .arcsec tag is used to convert the column depth
;     values to arcsec units:
;
;     coldepth_arcsec=dens.coldepth*dens.arcsec
;
; PROGRAMMING NOTES:
;     The routine takes the intensity and intensity-error from the
;     .int and .interr tags of the fitdata structures. It does not
;     make use of the parameters in the .aa tag. So if you want to
;     correct for a blend prior to calling eis_density, you can do it
;     by modifying the .int and .interr tags only.
;
; CALLS
;
;     ERRORS, EIS_GET_FITDATA, READ_IONEQ, READ_ABUND, CONVERTNAME,
;     INTEGRAL_CALC
;
; HISTORY
;
;     Beta 1, 18-Mar-2010, Peter Young
;     Beta 2, 11-Aug-2010, Peter Young
;       added check on muti-Gauss fits; now prints the theoretical
;       ratio lines and observed lines so user can manually check that
;       correct lines are being used.
;     Ver.1, 5-May-2011, Peter Young
;       routine now adjusts intensity array of numerator for CCD
;       Y-offset; introduced /NO_YSHIFT in case user does not want to
;       use this option. Added /QUIET keyword. Implemented missing
;       data value for all arrays, and added 'missing' as a tag to the
;       output structure.
;     Ver.2, 6-May-2011, Peter Young
;       Now calculates the column depth error and stores it in the
;       new .coldepth_err tag. Also added .arcsec tag.
;     Ver.3, 31-May-2011, Peter Young
;       For emission measure method of calculating column depth, the
;       density dependence of the integral is now included. 
;     Ver.4 25-Mar-2013, Peter Young
;       The routine now makes use of the new 'quick' tag in the RATIO
;       input in order to speed up the call to INTEGRAL_CALC. This
;       makes a significant performance improvement for the coronal
;       iron ions.
;     Ver.5, 24-Jan-2014, Peter Young
;       Added yshift_wvl= keyword.
;     Ver.6, 16-Jul-2014, Peter Young
;       Added abundfile= and ioneqfile= keywords; also added these as
;       tags to output to structure; yshift_wvl has also been added to
;       output.
;     Ver.7, 30-Jun-2015, Peter Young
;       Added CALIB= keyword for modifying the intensity calibration,
;       and added calib tag to output.
;     Ver.8, 24-Oct-2015, Peter Young
;       Added information to header; no change to code.
;     Ver.9, 5-Dec-2019, Peter Young
;       Updated default coronal abundance file to latest CHIANTI
;       file.
;     Ver.10, 28-oct-2024, Peter Young
;       Now handles the case where the measured ratio is outside of the
;       density sensitivity range of the theoretical ratio.
;-

IF n_params() LT 3 THEN BEGIN
  print,'Use:  IDL> dens = eis_density( fit1, fit2, ratio [, line1=, line2= /isothermal,'
  print,'                     yshift_wvl=, /quiet, /no_yshift, abund_file=, ioneq_file=,' 
  print,'                     calib= ])'
  print,'   fit1 - auto_fit structure for denominator line'
  print,'   fit2 - auto_fit structure for numerator line'
  print,'   ratio - structure returned by eis_chianti_dens_ratio.pro'
  return,-1
ENDIF 


IF fit1.nx NE fit2.nx OR fit1.ny NE fit2.ny THEN BEGIN
  print,'%EIS_DENSITY:  the array sizes of FIT1 and FIT2 are incompatible. Please check your inputs.'
  print,'               Returning...'
  return,-1
ENDIF

nx=fit1.nx
ny=fit2.ny

IF fit1.ngauss GT 1 THEN BEGIN
  IF n_elements(line1) EQ 0 THEN BEGIN
    print,'Fit structure 1 contains '+trim(fit1.ngauss)+' Gaussians. Please specify which Gaussian'
    print,'to use by specifying the LINE1 input.'
    print,'Returning...'
    return,-1
  ENDIF
ENDIF ELSE BEGIN
  line1=0
ENDELSE 

IF fit2.ngauss GT 1 THEN BEGIN
  IF n_elements(line2) EQ 0 THEN BEGIN
    print,'Fit structure 2 contains '+trim(fit2.ngauss)+' Gaussians. Please specify which Gaussian'
    print,'to use by specifying the LINE2 input.'
    print,'Returning...'
    return,-1
  ENDIF
ENDIF ELSE BEGIN
  line2=0
ENDELSE 


IF n_elements(calib) EQ 0 THEN calib=0


;
; The YSHIFT_WVL keyword shifts INT2 in Y in order to
; spatially match INT1. Sub-pixel shifts are allowed for.
;
IF n_elements(yshift_wvl) NE 0 THEN BEGIN
  int1=eis_get_fitdata(fit1,/int,err=int1_err,line=line1,yshift_wvl=yshift_wvl,calib=calib)
  int2=eis_get_fitdata(fit2,/int,err=int2_err,line=line2,yshift_wvl=yshift_wvl,calib=calib)
ENDIF ELSE BEGIN 
  IF keyword_set(no_yshift) THEN yshift_wvl=0. ELSE yshift_wvl=fit1.refwvl[line1]
  int1=eis_get_fitdata(fit1,/int,err=int1_err,line=line1,calib=calib)
  int2=eis_get_fitdata(fit2,/int,err=int2_err,line=line2,yshift_wvl=yshift_wvl,calib=calib)
ENDELSE 
wvl1=fit1.refwvl[line1]
wvl2=fit2.refwvl[line2]

IF NOT keyword_set(quiet) THEN BEGIN 
  print,''
  print,'Theoretical ratio is: ',trim(ratio.num_wvl)+'/'+trim(ratio.den_wvl)
  print,'Observed ratio is: ',trim(string(format='(f12.3)',wvl2))+'/'+trim(string(format='(f12.3)',wvl1))
  print,''
ENDIF

IF n_elements(ioneqfile) NE 0 THEN BEGIN
  chck=file_search(ioneqfile)
  IF chck[0] EQ '' THEN BEGIN
    print,'% EIS_DENSITY: specified ion balance file not found. Please check your inputs.'
    print,'               Returning...'
    return,-1
  ENDIF
ENDIF ELSE BEGIN
  ioneqfile=!ioneq_file
ENDELSE 

;
; Compute ratio and error
;
errors, int2, int2_err, int1, int1_err, rat, err

missing=fit1.missing
i_miss=where(int2 EQ missing OR int1 EQ missing,n_miss)
IF n_miss NE 0 THEN rat[i_miss]=missing

rat_theory=ratio.ratio
dens=ratio.dens
em_sum=ratio.em_sum

;
; ratio_type=1 if the ratio increases with density, and 0 if it decreases.
;
IF rat_theory[-1] GT rat_theory[0] THEN ratio_type=1b ELSE ratio_type=0b

;
; Interpolate onto 0.001 dex intervals
;
nd=(max(dens)-min(dens))*1000.+1
densi=findgen(nd)/1000.+dens[0]
y2=spl_init(dens,rat_theory)
rati=spl_interp(dens,rat_theory,y2,densi)
;
y2=spl_init(dens,em_sum)
em_sumi=spl_interp(dens,em_sum,y2,densi)

;
; Re-define density values
;
rat_theory=rati
dens=densi
em_sum=em_sumi


outdens=make_array(nx,ny,/float,value=missing)
hidens=outdens
lodens=outdens
;hidens=fltarr(nx,ny)
;lodens=fltarr(nx,ny)
emiss=fltarr(nx,ny)

;
; Go through each pixel in raster and compute density and the upper
; and lower limits. The emissivity sum at each location is also stored
; as this used to compute the isothermal column depth.
;
; 28-Oct-2024: I now check if the ratio is above or below the
; sensitivity range. If yes, then density is set to missing. If the
; upper or lower limit on the ratio lies within the sensitivity range
; then lodens or hidens will be set 
;
FOR i=0,nx-1 DO BEGIN
  FOR k=0,ny-1 DO BEGIN
    CASE 1 OF
     ;
      rat[i,k] GE max(rat_theory): BEGIN
        rat_err=rat[i,k]-err[i,k]
        IF rat_err LT max(rat_theory) THEN BEGIN
          getmin=min(abs(rat_theory-(rat_err)),j)
          IF ratio_type EQ 1 THEN BEGIN
            lodens[i,k]=dens[j]
          ENDIF ELSE BEGIN
            hidens[i,k]=dens[j]
          ENDELSE 
        ENDIF
      END
     ;
      rat[i,k] LE min(rat_theory): BEGIN
        rat_err=rat[i,k]+err[i,k]
        IF rat_err GT min(rat_theory) THEN BEGIN
          getmin=min(abs(rat_theory-(rat_err)),j)
          IF ratio_type EQ 1 THEN BEGIN
            hidens[i,k]=dens[j]
          ENDIF ELSE BEGIN
            lodens[i,k]=dens[j]
          ENDELSE 
        ENDIF
      END
     ;
      ELSE: BEGIN 
        getmin=min(abs(rat_theory-rat[i,k]),j)
        outdens[i,k]=dens[j]
       ;
       ; Store emissivity sum for pixel
       ;
        emiss[i,k]=em_sum[j]
       ;
        getmin=min(abs(rat_theory-(rat[i,k]+err[i,k])),j)
        hidens[i,k]=dens[j]
       ;
        getmin=min(abs(rat_theory-(rat[i,k]-err[i,k])),j)
        lodens[i,k]=dens[j]
      END
    ENDCASE 
  ENDFOR
ENDFOR



;;
;; THE FOLLOWING SECTION OF CODE IS FOR COMPUTING THE COLUMN DEPTH 
;; --------------------------------------------------------------

convertname,ratio.ion,iz,ion


;
; This indicates if the quick method for integral_calc should be used.
;
IF tag_exist(ratio,'quick') EQ 1 THEN BEGIN
  quick=ratio.quick
ENDIF ELSE BEGIN
  quick=0
ENDELSE 


;
; The following loads up the element abundance. If abundfile= has been
; specified, then is used. Otherwise the software tries to use the
; coronal abundance file in CHIANTI. If this is not found for some
; reason, then the routine defaults to !abund_file which is a standard
; photospheric abundance file.
;
IF n_elements(abundfile) NE 0 THEN BEGIN
  chck=file_search(abundfile)
  IF chck[0] EQ '' THEN BEGIN
    print,'% EIS_DENSITY: specified abundance file not found. Please check your inputs.'
    print,'               Returning...'
    return,-1
  ENDIF
ENDIF ELSE BEGIN
  ab_dir=file_dirname(!abund_file)
  abundfile=concat_dir(ab_dir,'sun_coronal_1992_feldman_ext.abund')
  chck=file_search(abundfile)
  IF chck EQ '' THEN abundfile=!abund_file
ENDELSE 
read_abund,abundfile,ab,ref
ab=ab[iz-1]
IF NOT keyword_set(quiet) THEN BEGIN
  print,'Column depth calculation'
  print,'  Abundance file: '+trim(abundfile)
  print,'  Ion balance file: '+trim(ioneqfile)
  print,''
ENDIF 


IF NOT keyword_set(isothermal) THEN BEGIN 
 ;
 ; ---- Compute column depth using emission measure method ----
 ;
 ; The density enters into the emission measure integral and so it is
 ; necessary to compute the integral for each pixel individually. This
 ; is very time consuming so the solution is to compute the integral
 ; for a range of densities between the MIN(DENS) and MAX(DENS), spaced
 ; at 0.5 dex intervals. The returned function will be a smoothly
 ; varying function of density and so I interpolate onto a very fine density
 ; scale. I then go through each pixel of the OUTDENS array and take
 ; the integral value that corresponds to the density in that pixel.
 ; This speeds up the process greatly while keeping the necessary
 ; accuracy. 
 ;
 ; 25-Mar-2013: since CHIANTI 7.1, the call to integral_calc has become
 ; extremely slow due to the very large models for the coronal iron
 ; ions. To fix this I've introduced a quick method in
 ; integral_calc (see /quick keyword).
 ;
 ;  Compute integral for sparse density intervals
 ;
  n_int=round((max(dens)-min(dens))/0.5)+1
  dens_int=findgen(n_int)*0.5+min(dens)
  int_calc=dblarr(n_int)
 ;
  IF quick EQ 1 AND NOT keyword_set(quiet) THEN BEGIN
    print,''
    print,'  **Warning: this calculation may take several minutes.**'
    print,''
  ENDIF
 ;
  FOR i=0,n_int-1 DO BEGIN 
    integral_calc,iz,ion,dens=dens_int[i],index=[ratio.num_ind,ratio.den_ind], $
                  outstr=outstr, quick=quick, /quiet
    int_calc[i]=outstr.pidec
  ENDFOR
  emiss_out=0
 ;
 ;  Interpolate integral onto much finer density scale.
 ;
  nd=round((max(dens)-min(dens))*1000.+1)
  densi=findgen(nd)/1000.+dens[0]
  y2=spl_init(dens_int,int_calc)
  int_calc_i=spl_interp(dens_int,int_calc,y2,densi)
 ;
 ;  Compute integral array pixel-by-pixel using nearest density
 ; 
  ic_array=fltarr(nx,ny)+missing
  FOR i=0,nx-1 DO BEGIN
    FOR j=0,ny-1 DO BEGIN
      IF outdens[i,j] NE missing THEN BEGIN
        getmin=min(abs(outdens[i,j]-densi),k)
        ic_array[i,j]=int_calc_i[k]
      ENDIF 
    ENDFOR
  ENDFOR 
 ;
 ;  Compute column depth
 ;
  coldepth=(int1+int2)*ic_array/ab/(10.^outdens)^2
 ;
 ;  Set missing data
 ;
  IF n_miss NE 0 THEN coldepth[i_miss]=missing

ENDIF ELSE BEGIN

;------- Compute column depth using isothermal approximation ------
;
; This approach assumes the plasma is isothermal at the T_max of the
; ion.
;
 ;
 ; Determine the ionization fraction (f_of_t) for the T_max of the ion
 ;
  read_ioneq,ioneqfile,tt,ii,ref
  ii=reform(ii[*,iz-1,ion-1])
  f_OF_t=max(ii)
 ;
  alpha=4.0*!pi/0.83/ab/f_OF_t /emiss
 ;
  coldepth=alpha*(int1+int2)/10.^outdens
 ;
  IF n_miss NE 0 THEN coldepth[i_miss]=missing
ENDELSE 

;
; Compute column depth error (see EIS Software Note #15)
;
sig_i2=int1_err^2+int2_err^2
a=-2.0*alog(10.)
sig_n= ( ( hidens-outdens ) + ( outdens-lodens ) )/2.
coldepth_err=sqrt(sig_i2*coldepth^2/(int1+int2)^2 + sig_n^2 * a^2 * coldepth^2)

IF n_miss NE 0 THEN coldepth_err[i_miss]=missing


dens=10.^outdens
IF n_miss NE 0 THEN BEGIN
  dens[i_miss]=missing
  lodens[i_miss]=missing
  hidens[i_miss]=missing
ENDIF 


dens={ldens: outdens, $
      dens: dens, $
      lo: lodens, $
      hi: hidens, $
      ratio: rat, $
      coldepth: coldepth, $
      coldepth_err: coldepth_err, $
      arcsec: 1./7.2527e7, $
      abundfile: abundfile, $
      ioneqfile: ioneqfile, $
      yshift_wvl: yshift_wvl, $
      calib: calib, $
      missing: missing}

return,dens

END