SOHO DAILY REPORT Operations Day -- 356/1995 (12-22-95) Mission Day 20 SOHO FLIGHT OPERATIONS TEAM, NASA/GSFC Ref. #: SH-FOT-DR-951221 =========================================================== PASS #1 Canberra DSS42 05:00:32 08:00:00 PASS #2 Madrid DSS66 09:36:51 13:32:14 PASS #3 Goldstone DSS16 15:06:00 22:20:00 PASS #4 Canberra DSS46 22:10:00 00:53:00 Pass#1 Summary --------------------- Anomalies: N/A Pass Activities: - Reset SSR SEF counters - Dump SSR - DHSS Good health check - ANTS Good health check - SSR to record Pass#2 summary --------------------- Anomalies: G-150: OPD 003 Failure (Implementation) - Station received direction via OPD 003 to set uplink sweep to +/- 60 kHz vice our normal +/- 120 kHz - FOT directed station to use +/- 120 kHz uplink sweep Activity Summary: - Dump SSR - AOCS Good Health - Power Budget CONFIGMON - Power Subsystem Good Health check - Reset SSR SEF counters - Placed SSR into record mode Pass#3 Summary --------------------- Anomalies: S-66: TCM Data error - FOT entered wrong value for data word (80 vice 8) - MOCR submitted on procedure to check value entered Activity Summary: - SSR Playback - Uplink new roll steering law table - OCD 130: Changed duty cycles for CELIAS Htr Circuit 64 to 40(nom)/80(red) - CELIAS Commissioning Block 1.11, 2.1.1, 2.2.2, 2.2.3 NRT: - 18:10-19:29 MDI, LASCO - 20:16-21:26 MDI, LASCO, SWAN Pass#4 Summary --------------------- Anomalies: G-152: Late Carrier Up - Station Power Amplifier (PA) #1 failed. Switched to PA #2 - Commanding delayed 3 minutes (DR #J9268) G-153: Block/Frame Sequence Errors - Station outputting two virtual telemetry streams to GSFC - Poor telemetry quality for 4 minutes (DR #J9269) Activity Summary: - SSR SEF counter reset - Quick health checks performed continuously - Dumped and reset min/max monitoring table and verified PROS B temperatures - Reset SSR SEF counters - SSR to record NRT: - 22:56 - 00:29 MDI, LASCO, SWAN --End of report--